Prothese Interphalangealgelenk
![](http://pacs.de/sites/default/files/pictures/thumbs/data.pacs.de/1/3/2/6/8/5/12891_2020_3687_Fig5_HTML_thumb.jpg)
Two-component
surface replacement implants compared with perichondrium transplantation for restoration of Metacarpophalangeal and proximal Interphalangeal joints: a retrospective cohort study with a mean follow-up time of 6 respectively 26 years. SBI implants at PIP level with different problems. The ring-finger was operated in 2012, and revised in 2015 as the distal component was changed and cemented. Subsequently the joint ended up ankylotic with bony overgrowth. The index and middle-finger were operated in 2016. This radiography from 2017 show signs of subsidence and deviation, especially in the index-finger which later had to be revised and cemented (both components). Only the middle-finger implant has survived without additional surgery
![](https://pacs.de/sites/default/files/pictures/thumbs/data.pacs.de/1/3/2/6/8/6/13018_2019_1234_Fig1_HTML_thumb.jpg)
Novel implant
design of the proximal interphalangeal joint using an optimized rolling contact joint mechanism. Plain radiograph images and coordinate frames for the middle and proximal phalanges. a Three-dimensional model of the proposed proximal interphalangeal joint (PIPJ) in full extension and maximal forward flexion. b Kinematic design of the proposed PIPJ implant illustrating the rolling contact surfaces and shapes of the extensor tendon route
![](https://pacs.de/sites/default/files/pictures/thumbs/data.pacs.de/1/3/2/6/8/7/13018_2019_1234_Fig2_HTML_thumb.jpg)
Novel implant
design of the proximal interphalangeal joint using an optimized rolling contact joint mechanism. A three-dimensional model of the proximal interphalangeal joint (PIPJ) using the rolling contact joint mechanism. a Contours of the proximal (green) and middle (blue) phalangeal bones and the base (Σb), proximal (Σp), and middle (Σm1) coordinate frames in full extension of the PIPJ. b The ith radiographic image and homogenous transformation (HT) matrices. c The average center of rotation (ACR) based on the HT matrices obtained from multiple radiographic images
![](https://pacs.de/sites/default/files/pictures/thumbs/data.pacs.de/1/3/2/6/8/8/12919_2015_Article_3117_Fig1_HTML_thumb.jpg)
Distal
interphalangeal hemiarthroplasty (ADIP): preliminary series of 14 cases. Figure 1
Prothese Interphalangealgelenk
Siehe auch:
und weiter:
![Click für weniger anzeigen](/sites/all/modules/pacs/tools/imgs/collapse_up.png)
![](/sites/all/modules/pacs/tools/imgs/Iris_color_40.png)