Caldwell view
Facial bones
(Waters view) • Skull positioning lines (diagram) - Ganzer Fall bei Radiopaedia
Facial bones
(Waters view) • Normal facial bones series - Ganzer Fall bei Radiopaedia
Gunshot
injuries • Facial gunshot injury - Ganzer Fall bei Radiopaedia
Skull
(Caldwell view) • Caldwell view - Ganzer Fall bei Radiopaedia
Skull
(Caldwell view) • Caldwell view - Ganzer Fall bei Radiopaedia
Skull
(Caldwell view) • Black eyebrow sign - orbital emphysema - Ganzer Fall bei Radiopaedia
Facial bones
(Waters view) • Cranial landmarks (photo) - Ganzer Fall bei Radiopaedia
The Caldwell view is a caudally angled radiograph, with its posteroanterior projection allowing for minimal radiation to the orbits. This view may be used in imaging of the skull or facial bones depending on the clinical indications.
Indications
This view aids in visualizing the paranasal sinuses, especially the frontal sinus. It can help to assess inflammatory conditions such as sinusitis and secondary osteomyelitis, and sinus polyps or cysts. Additionally, any fractures to the orbit may also be determined through this view.
Patient position
- the patient is seated in front of the upright detector
- the patient's forehead is placed against the image detector
- forehead and nose are both touching the detector
- the orbitomeatal line (OML) is running perpendicular to the detector
- petrous ridge is below orbits
Technical factors
- posteroanterior (PA) projection
- centering point
- angled caudad around 15° to exit at the nasion
- collimation
- lateral to the skin margins
- superior and inferior to the borders of the sinus cavities
- orientation
- portrait
- detector size
- 24 cm x 30 cm
- exposure
- 70-80 kVp
- 20 mAs
- SID
- 100 cm
- grid
- yes
Image technical evaluation
- no rotation evident via the symmetrical nature of the orbits
- the innominate lines should be equidistant from the lateral borders of the orbits
- petrous ridges are projected in the lower third of the orbits
- no tilting should be evident; an imaginary line through the petrous ridges should be horizontal
Practical points
- always guarantee that the patient is not 'hunched' over when they are being examined. This can cause an artifact from the shoulders and the patient is more likely to be rotated; it is best to move the chair up close to the detector so they are sitting up straight for the image
- remember, having one's head against an upright detector is uncomfortable, so try to have everything set up before you position the patient, to ensure patient comfort
- constantly use a side marker and regularly place it PA. Skulls can get tricky with figuring out which side is which. Many vendors tend to 'flip' images to make them appear AP
History and etymology
The view was first described by E. W. Caldwell in 1907 .