endotracheal tube in right main bronchus

Tubus im rechten Hauptbronchus
endotracheal tube in right main bronchus
Intubationskomplikationen Radiopaedia • CC-by-nc-sa 3.0 • de
A misplaced or malpositioned endotracheal tube is a relatively common complication that is detected on post-intubation radiographs.
Complications
- if the ETT is too high it can rub against the vocal cords and cause cord trauma
- if the ETT is too low it can selectively intubate the right or left mainstem bronchus (see: endobronchial intubation)
- esophageal intubation should be suspected with progressive gaseous distention of the stomach while the lung volumes remain low
Differential diagnosis
Siehe auch:
und weiter: