MRT Sellink
MR-Enteroklyse
(MR-Sellink) bei Morbus Crohn mit langstreckigem Befall des terminalen Ileums, T1w FS KM
MR-Enteroklyse
(MR-Sellink) bei Morbus Crohn mit langstreckigem Befall des terminalen Ileums, T2w FS
MR-Enteroklyse:
Morbus Crohn mit Manifestation im terminalen Ileum. Oben DWI axial, T2 FS coronar, unten zwei Schichten T1 FS KM coronar. Links unten ist besonders gut der Bereich der Ileozökalklappe sichtbar.
MR enterography (MRE) is a non-invasive technique for the diagnosis of small bowel disorders.
Note: This article is intended to outline some general principles of protocol design. The specifics will vary depending on MRI hardware and software, radiologist's and referrer's preference, institutional protocols, patient factors (e.g. allergy), and time constraints.
Indications
MR enterography, in an analogous way to CT enterography, is most commonly used to evaluate patients with Crohn disease where it is used for assessment of the primary disease and any complications. Other indications include celiac disease, postoperative adhesions, radiation enteritis, scleroderma, small bowel malignancies, and polyposis syndromes.
Advantages
- no ionizing radiation
- excellent soft tissue contrast resolution
- images can be acquired in customized planes
Disadvantages
- longer scanning time
- more susceptible to motion and breathing artefacts
- MRI incompatible implants or devices may preclude the scan
Technique
Bowel preparation
- abstinence from all food and drink for 4-6 hours prior to the study
- oral administration of 1-1.5 L of 2.5% mannitol solution at regular intervals over a period of approximately 40 minutes prior to the study
- hyperosmolar mannitol draws fluid into the bowel
- provides biphasic improved MRI soft tissue contrast:
- low signal intensity on T1-weighted images
- high signal intensity on T2-weighted images
Sequences
- comprehensive MR examination of the small bowel usually requires axial and coronal T1 and T2 weighted images
- high-resolution ultra-fast sequences such as true fast imaging with steady-state precession (true FISP)
- HASTE sequence or other T2 with fat suppression
- fat-suppressed three-dimensional (3D) T1-weighted breath-hold gradient-echo images of the abdomen and pelvis before and after intravenous gadolinium-based contrast material administration
See also
Siehe auch:
- Morbus Crohn
- Enteroklysma
- CT enteroclysis
- bright lumen Technik
- diffusion weighted imaging in crohn disease
- dark lumen Technik
und weiter:
Assoziationen und Differentialdiagnosen zu MR Sellink: