Verletzung mit Druckluftnagler

Fremdkörper durch Verletzungen


Fremdkörper RadiopaediaCC-by-nc-sa 3.0de

Foreign bodies are objects lying partially or wholly within the body that originated in the external environment. Foreign body placement is voluntary or involuntary. Although implanted medical devices represent foreign bodies in the broad sense of the term, these have their own set of articles (see below).

Pathology

Etiology

There are many ways in which a foreign body can be introduced into various parts of the human body.

Aspirated

Aspirated foreign bodies will have a clear clinical correspondence: choking, coughing, neck pain or struggling to breathe. Risk factors for foreign body aspiration include intubation, neurological deficit, facial trauma, and dental instrumentation. The right main bronchus is the most common site of obstruction due to the anatomy of the bronchial tree favoring the right side (larger diameter, more vertical orientation). Often two orthogonal plain radiographs are the primary investigation of choice .

Iatrogenic

Many surgical procedures deliberately introduce foreign bodies either deliberately in the form of hemostatic clips (most common), stents, valve replacements, pacing boxes, catheters, etc., or accidentally when a surgical instrument or surgical pack are inadvertently left in situ.

Ingested

Ingested foreign bodies range from pediatric patients placing objects in their mouths, to mental-health-related self-harm, to bones stuck in the pharynx or gastrointestinal tract. Coins account for 70% of pediatric ingested foreign bodies and will typically become ‘stuck’ at the level of the cricopharyngeus muscle .

Sharp ingested foreign bodies can be potentially problematic when lodged in the esophagus, patients will often require emergency endoscopy, more often than not if the sharp object is within reach of endoscopy it will be removed before it progresses further .

Plastic bread clips are diagnostically challenging, the limited literature on this foreign body suggests they are invisible on both plain radiography and CT, and the rigid shape can cause bowel perforations or gastrointestinal hemorrhage .

Drug packing

Drug packing is a well-documented form of foreign body. Often drugs are placed within condoms, or wrapped in foil, latex or cellophane, then swallowed or inserted anally or vaginally. These should be considered hazardous to the patient until evacuated due to the possibility of the containment method rupturing.

Rectal

Most rectal foreign bodies are inserted via the anus, although occasionally the foreign body has been ingested and has passed through to lie in the rectum. Commonly, rectal foreign bodies are used for sexual purposes . Rectal foreign will vary from case to case. The main problem with this is the often delayed presentation due to the reluctance of patients to present to emergency departments. Patients may suffer from extraperitoneal mucosal injuries or suffer from a more severe complication such as perforation .

Two plain radiographs are recommended to accurately demonstrate the size, shape, and location of the rectal foreign body. This should be performed before a digital examination to prevent staff-related injuries from sharper foreign bodies.

Soft tissue

Most soft tissue foreign bodies are involuntary, resulting from accidental injury . The most commonly reported soft-tissue foreign bodies are glass, metal, and splinters from wood  and the most common location is the wrist/hand/finger .

It is imperative to locate foreign bodies before they become infected or worse, such as damage close-by organs, ideally within 24 hours of injury . ~40% are missed on clinical examination . Patients may have a delayed presentation with a foreign body granuloma.

Radiographic features

The investigation of foreign bodies relies heavily on radiology and every foreign body will have an optimal modality for investigation . Metal, glass, and stone can be visualized very well using conventional plain film radiography, whereas more organic structures, such as wood, may require further imaging such as ultrasonography.

Plain radiographs

The radiological appearance in plain radiography of foreign bodies is dependent on three factors: the x-ray attenuation of the foreign body, the surrounding structures and any overlying structures that may veil the object.

The anatomical location will not only affect the radiopacity of the suspected foreign body, but the rate of magnification as the object is placed further or closer to the detector, lateral cervical radiographs can have a magnification rate of up to 21.6% .

Ultrasound

Most foreign bodies are hyperechoic.

CT

The density of the foreign material in the body can range markedly, so the use of multiple window settings is crucial in identifying the presence of the objects. Routinely soft tissue, lung, and bone windows should be assessed. Certain plastics may be occult on CT.

MRI

The signal intensity of the foreign material in the body can range markedly, but most objects cause artifacts of some sort. Certain objects may be occult on MRI, such as those made of wood or plastic.

See also

Siehe auch: