endovascular aneurysm repair (EVAR)
Endovascular aneurysm repair (EVAR) was first pioneered in the early 1990s. Since then the technology of the devices has rapidly progressed and EVAR is now widely used as a treatment of thoracic and abdominal aortic aneurysms (AAA).
The advantages of endovascular repair over open repair are that they are less invasive than open surgery, have a lower surgical morbidity and mortality rate, and they reduce the length of postoperative stay in hospital. Disadvantages include the need for life-long follow-up imaging, and the long-term durability of graft material is yet to be proven.
Subtypes
- FEVAR: fenestrated endovascular aneurysm repair
- BEVAR: branched endovascular aneurysm repair
Location-specific types
Indications
EVAR is performed in patients undergoing elective aneurysm repair as well as patients undergoing emergency repair (e.g. traumatic aortic injury and ruptured AAA).
Contraindications
Relative contraindications include:
- narrow iliac arteries, e.g. ~8 mm
- sharply angulated iliac arteries
- short aneurysmal neck
- tapering aneurysmal neck
- highly likelihood of graft occluding a visceral vessel once deployed
Procedure
EVAR is performed by inserting a stent-graft into the lumen of the aneurysmal portion of the aorta. The stent-graft consists of a graft that provides a conduit for blood flow and a stent that anchors the graft to the aorta and provides structural support for the graft material. The aim is to divert blood flow into the graft, thereby bypassing the aneurysm.
Pre-procedure evaluation
The key to successful EVAR is proper pre-procedural planning. Not all aneurysms are suitable for EVAR, depending on the anatomy of the aneurysm and iliac vessels. For those deemed suitable, careful aneurysm measurements (usually with CTA) will ensure the graft is the correct length and diameter. If the graft is too short the aneurysm will not be excluded from the circulation; if it is too long important branch vessels may be inadvertently occluded; if it is too narrow in diameter, there will not be an adequate seal against the aortic wall which may result in an endoleak.
The pre-EVAR CTA also needs to assess the access vessels (i.e., the CFA, EIA, and CIAs) to document any atherosclerotic disease as well as the diameters of these vessels (for passage of the device delivery systems).
Equipment
Stent-grafts are made in a number of configurations. In AAA repair, the most common configuration is a bifurcated graft extending from the aorta into the common iliac or external iliac arteries. This typically requires access via both common femoral arteries. The grafts are modular in construction, that is they are assembled in the patient in stages. The main body is deployed first, followed by the iliac limbs. The materials used in the stent-graft vary with each manufacturer but most grafts are made of expanded polytetrafluoroethylene (ePTFE) or woven polyester, and most stents are made of nitinol or stainless steel.
Technique
Depending on the institution, EVAR is performed by interventional radiologists, vascular surgeons, or both together. The patient typically requires a general anesthetic.
A stent-graft is inserted via the common femoral artery and deployed once it is confirmed in adequate position under the image intensifier, similar to other types of stent insertion. However, the diameter of the stent-graft and its delivery device are large (usual delivery device size ranges between 18 and 24 French). Thus the procedure typically requires surgical exposure and closure of the common femoral artery, although percutaneous arterial access methods are also available.
Adjunctive procedures
Adjunctive procedures are sometimes required to improve the technical success of EVAR just prior to or during the endovascular repair. These include angioplasty of stenoses before device delivery, angioplasty of stenosis in the graft, embolization of branch vessels to prevent endoleak, and stent reinforcement of endograft limb.
Complications
Recognized complications include:
- endoleak: occurs in 30-40%
- continued enlargement of the aneurysm sac without endoleak (endotension): 2-40%
- delayed aneurysm rupture
- stent-graft migration
- limb kinking
- branch vessel occlusion with end-organ ischemia/infarction
- infection
- stent-graft structural breakdown
- groin complications
Patients require life-long imaging surveillance to monitor for endoleak, aneurysm expansion, and graft integrity. This is most commonly performed via CTA. MRA is an alternative but stainless steel stents cause major susceptibility artefact that limits its usefulness in such cases.
Different CT techniques have been advocated:
- single-phase CTA
- dual-phase CTA: non-contrast and arterial phase, or arterial and delayed phase
- triple-phase CTA: non-contrast, arterial phase, and delayed phase
The need for non-contrast and delayed phase images is controversial, particularly in light of the cumulative radiation dose the patient will receive over the rest of their life. However, delayed imaging is felt to be important in order to detect slow endoleaks that do not show in the arterial phase.
Outcomes
For elective AAAs compared to open repair, EVAR shows improved 30-day operative mortality but this is not sustained by five years. There are also higher rates of delayed complications and re-intervention in EVAR . However, for ruptured AAAs EVAR may demonstrate reduced peri-operative and longer-term (four years) mortality compared to open repair .
Siehe auch:
- Bauchaortenaneurysma
- endovaskuläre Therapie des Bauchaortenaneurysmas
- Endoleaktypen
- Thorakale endovaskuläre Aortenreparatur
- Nellix EndoVascular Aneurysm Sealing System
- Aortentrauma
und weiter:
- inflammatory abdominal aortic aneurysm
- Type IV endoleak
- Interventionelle Therapie Aortenaneurysma
- Endoleak Typ 1 (Graftende nicht anliegend)
- Nellix Aortenprothese
- EVAR bei TAA
- endovascular AAA stent-grafting
- distal limb migration after endovascular AAA stent-grafting treated by percutaneous covered stent placement.
- EVAR follow up